There is no single LED-module spacing that suits every light box. Start with the exact module’s layout guidance, then test it with the final face material and frame. First identify whether the modules point forward from the rear panel or shine inward from the frame edges: these arrangements require different layouts.
Define the dimensions before drawing the layout
For rear-facing modules, record the distance from the emitting surface to the diffuser or graphic, row spacing, spacing along each row and the first module’s offset from the edge. State whether dimensions are centre-to-centre or clear gaps. For edge-mounted bars, record their spacing along the frame, the distance light must travel across the box and the lens orientation. Cabinet depth alone does not describe that optical path.
Include internal rails, corners, cable routes, reflective surfaces and the number of illuminated faces. Use the actual fabric, acrylic, diffuser and print construction. A plain sample does not establish the result with a different final graphic, and a double-sided box needs checks on both faces.
Use the exact model’s guidance as a starting point
A regular grid can be a candidate for rear-facing modules. Edge-lighting bars instead need placement along suitable inner frame edges with their lenses aimed into the cavity. Do not apply one system’s grid to the other or choose pitch from wattage alone. Lens distribution, module dimensions, face transmission and the path across the box all affect the result.
For example, the 20W rigid edge-lighting bar is listed at 470 × 24 × 16mm, including the lens, with a 10° × 40° optic and DC24V constant-voltage input. It is not a generic rear-facing grid module. The product page’s approximate 50cm spacing is only an initial test point for some builds, not a universal recommendation or a promise of even illumination.
SloanLED’s Prism24 density guidance illustrates why manufacturer tables are specific to a product, cabinet depth and face material. It calls for a sample test and describes the guidance as approximate. Its spacing and electrical limits must not be transferred to BOOTH LIGHTS modules.
Build a representative trial, then check the whole box
- Mark the proposed positions, edge offsets and lens direction. Confirm mounting and connector clearance before fitting parts.
- Use the intended frame, internal surfaces and final face material. Include a corner and any rail that could interrupt the light path.
- Power the trial with the specified supply and feed arrangement. Check polarity and compatible wiring before energising.
- Inspect the face at the intended viewing distance and under the expected ambient light. Check centre, edges, corners and areas beside structural members.
- Record positions and defects, change one layout variable at a time and compare under the same conditions.
A small section can screen a proposed layout, but it cannot prove the centre of a wider box will be bright enough or both faces will match. Verify the complete box before fixing a production layout. Use photographs to document positions and visible patterns; they are not calibrated brightness measurements. Agree a suitable measurement method if the project has a numerical brightness or uniformity requirement.
Diagnose the pattern before adding modules
| Observed pattern | What to check next |
|---|---|
| Bright dots or bands on the face | Optical orientation, source-to-face distance, row or bar spacing and the actual diffuser. |
| Bright edges with a dark centre | Edge-bar direction, the distance across the box, opposing-edge placement and internal obstructions. |
| Dark corners or a shadow beside a rail | Edge offsets, corner placement and whether the structure blocks the beam. |
| A section is dim or changes brightness along a feed | Have the electrical designer check connections, supply loading and voltage at the modules under load before treating it as a spacing fault. |
These are checks, not diagnoses from a photograph. More modules may help an optical gap, but they cannot automatically fix incorrect orientation, a blocked light path or unsuitable power. Keep any required mounting and thermal clearances.
Recalculate power whenever the layout changes
Every added bar changes the connected load. Four nominal 20W bars total 80W of nominal module power; that arithmetic does not select a complete driver or wiring system. This model requires an external compatible DC24V constant-voltage supply, which is not included. Size the supply, feeds and connectors for the final load, operating conditions and appropriate design margin. Confirm connector pinout and polarity rather than relying on the connector’s shape.
Record the accepted module model, quantity, positions, face construction, lens direction and power arrangement. Recheck after changing any of them. Compare alternatives in LED light-box modules using their own instructions and a trial of the actual assembly.