A laboratory report is useful only when its tested sample matches the module you plan to buy. Ask for the complete report before relying on a numerical summary, a laboratory name or an accreditation logo. A report for another model or configuration does not establish the performance of your order.
Start with the original document
- Check the report number, issue date, laboratory identity and a way to verify the document with its issuer.
- Match the sample model, dimensions, lens, LED configuration and selected color temperature to the quoted product.
- Read the test method, supply voltage, temperature, stabilization conditions and measurement uncertainty where stated.
- Check the laboratory's accreditation scope for the actual method. Accreditation is not blanket product approval.
China's official catalogue identifies GB/T 24824-2009 as measurement methods for general-lighting LED modules. Naming a standard does not prove that a particular sample was tested to it. Global ACI explains that accreditation and international recognition depend on the relevant scope; acceptance by a destination's regulator or buyer is not automatic.
Read the measurements in context
Lumens describe light output; watts describe power. Calculate lm/W using measured output and the corresponding measured power, and check whether power is measured at the DC module or includes its driver. CCT describes light color, while Ra/CRI describes color fidelity. DOE notes that CRI has limitations and that power-supply efficiency affects system performance. Neither a high CCT nor fabric diffusion guarantees accurate brand colors. Beam angles describe distribution in two axes; they do not guarantee uniformity in a finished lightbox.
Keep current product specifications separate
The following are current listing specifications, not independently verified laboratory results:
| Model | Published specifications |
|---|---|
| 10W slim edge-lit bar | DC24V; 1100 lm; CRI 90+; 360 × 23 × 16mm including lens; 9° × 50° optics. |
| 12W/18W MODULAP-compatible module | DC24V; 1320/1980 lm respectively; CRI ≥90; 470 × 23 × 16mm including lens; 9° × 50° optics. |
Both require a compatible external DC24V constant-voltage driver, which is not included. Confirm the selected variant, connectors and wiring limits; do not transfer another sample's results to either listing.
Verify the finished display
Test actual frame depth, module spacing, reflective surfaces and printed fabric. Inspect uniformity and colors with the intended driver and layout. An initial photometric test does not by itself prove lifetime, electrical safety, certification or the performance of a complete installation.
Contact BOOTH LIGHTS with the product link, selected variant, frame drawing and driver plan. Ask which report, if available, corresponds to that configuration and what it covers. Compare other formats in the lightbox module collection, and retain the matching document with the order.