A 10×10-foot booth is approximately 3.05×3.05 m. That floor area does not tell you how many fixtures will illuminate the display. Plan the actual surfaces, test the proposed arrangement, then confirm mounting and electrical approval.
Map the surfaces before choosing quantity
Mark the back-wall graphic, product shelves, counter and visitor positions on a drawing. Record graphic height, mounting distance and permitted attachment points. A backlit lightbox needs its own internal lighting plan; arm lights do not replace that system.
Compare output and beam, rather than watts alone
| Model | Published output | Colour setting |
|---|---|---|
| 25W Tri-CCT | 2,500 lm | 3000K / 4500K / 6000K; button selected |
| 25W fixed-CCT | 3,250 lm | 3000K, 4500K or 6500K; selected at purchase |
These two published models use the same nominal wattage but have different light output. Both list a 120° beam. Test overlap on the real graphic at the intended distance. If trying two fixtures across a back wall, treat that as a trial, not a required quantity. Adjust positions before adding lights.
Check colour and glare on real materials
The Tri-CCT model selects three fixed settings; it is not continuously tunable. Compare available settings on your print and products alongside ambient light. Neither 4500K nor CRI 90+ guarantees an exact brand-colour match. Check reflections on screens and glossy surfaces from the aisle and seated visitor positions.
Rehearse the mount and cable route
Ask the stand supplier to approve the mounting points and fixture loads. Measure frame profile, clamp opening, clearance and arm reach; do not assume every frame is 1 or 2 inches. Assemble and connect with power disconnected, following the instructions. Protect cable routes, allow required heat clearances and keep connectors free of strain.
Confirm power and documents before dispatch
Give the show’s electrical provider the complete equipment list, including screens and demonstration devices. Use actual input ratings for the complete lighting kit and follow model-specific linking limits. Confirm voltage, plug, available circuit capacity, power-order charges and who may connect the equipment. Read the current event manual and obtain documentation for the exact model and configuration. A UL or ETL claim is not blanket approval for every venue; OSHA explains certification within a laboratory’s recognised scope.
Record an arrangement you can repeat
Save the approved fixture count, positions, aiming, colour setting and labelled cable layout. Recheck the result under hall lighting before opening. Include setup, disconnection and packing in the rehearsal; there is no universal five-minute installation time. Send the drawing and frame measurements when requesting a configuration.